To significantly improve accuracy and precision perform the test as follows:

Purchase 1 gallon of distilled water ($0.85).

1.  Into a clean measuring cup pour 15 ounces of distilled water

take measurement of distilled water if desired

2.  Add 1 ounce of your tap water

3.  Take the measurements as described previously

4.  Use the table or the chart to look up your TDS value

 

Read the value obtained from your reading on the left side of the Graph.

Find the point where the diagonal line crosses through that value and go straight down to obtain the TDS value that correspond to the Kohm (resistance) reading you obtained on the VOM.

Ex. The reading you obtained was 200 kohms. The corresponding TDS value will be approximately 325 PPM.

VOM - Adapter Reading Resistance in Kohms Approximate TDS Value in PPM
343.7 10
339.1 20
329.9 40
320.8 60
311.6 80
302.4 100
293.2 120
284.0 140
274.9 160
265.7 180
256.5 200
247.3 220
238.1 240
229.0 260
219.8 280
210.6 300
201.4 320
192.2 340
183.1 360
173.9 380
164.7 400
155.5 420
146.3 440
137.2 460
128.0 480
118.8 500
109.6 520
100.4 540
91.3 560
82.1 580
72.9 600

 

 